Datenblatt für FRB-NT Series von 3M

3MTM Flame Barrier FRB-NT Series — Description 3MTM Flame Barrier FRBVNT Series provides the high flammability resistance, arc resistance, and dielectric strength to help safely contain electrical hazards. These barriers are available in roll or sheet lorm. The flame barrier FRBVNT series provides the reliability you need lrom 3M, a trusted company with over 30 years of experience providing insulating solutions that protect people, equipment, and property around the globe. Applications The flame barrier FRBVNT series provides both electric shock and flame protection lor electrical and electronic device applications such as: . General purpose lighting luminaires (including LED type) . Battery housing barrier (including electric and hybrid vehicles) . Appliance enclosure (e.g., timers, actuators, switches) Features The flame barrier FRBVNT series is: . An inorganicrbased, halogen free material (see regulatory section) . UL 9475VA rated , the most flame retardant UL 94 rating, even better than UL 94V70 - Dimensionally stable , minimal to no shrinkage at elevated temperatures Low
1 of 4 3
3M™ Flame Barrier FRB-NT Series
Description 3M™ Flame Barrier FRB-NT Series provides the high flammability resistance, arc resistance,
and dielectric strength to help safely contain electrical hazards.
These barriers are available in roll or sheet form.
The flame barrier FRB-NT series provides the reliability you need from 3M, a trusted
company with over 30 years of experience providing insulating solutions that protect people,
equipment, and property around the globe.
Applications The flame barrier FRB-NT series provides both electric shock and flame protection for
electrical and electronic device applications such as:
General purpose lighting luminaires (including LED type)
Battery housing barrier (including electric and hybrid vehicles)
Appliance enclosure (e.g., timers, actuators, switches)
Features The flame barrier FRB-NT series is:
An inorganic-based, halogen free material (see regulatory section)
UL 94-5VA rated - the most flame retardant UL 94 rating, even better than UL 94V-0
Dimensionally stable – minimal to no shrinkage at elevated temperatures
Available in thicknesses from 3 to 15 mil (0.08 to 0.38 mm)
Densified for high dielectric strength and smooth surface
Low volatile outgassing
Regulatory The flame barrier FRB-NT series is:
REACH compliant. Product contains no Substances of Very High Concern (SVHC’s) on the
REACH candidate lists according to article 59 of Regulation (EC) No 1970/2006 up to June 2012.
For current status, go to www.3M.com/REACH
RoHS Meets MCVs 2011/65/EU. "RoHS meets MCVs" means that the product or part does
not contain any of the substances in excess of the maximum concentration values (“MCVs”) in EU
RoHS Directive 2011/65/EU. The MCVs are by weight in homogeneous materials.
Halogen Free defined as both 1) no halogen compounds are intentionally added to the product or used in
the manufacturing process for the product and 2) any impurities present are less than 900 ppm bromine, less
than 900 ppm chlorine, and/or less than 1500 ppm total bromine and chlorine. The latter are the levels set forth
in certain industry standards, such as the International Electrotechnical Commission (IEC) 61249-2-21 standard.
The above information represents 3M’s knowledge and belief which may be based in
whole or in part on information provided by 3rd party suppliers to 3M.
UL component recognized in accordance with UL 746 file # E65069
Flammability The UL 94 test method is used to classify materials based on results from specified small-
scale flame tests. These classifications (5VA, 5VB, V-0, V-1, V-2, HB, listed in decreasing
order of flame resistance) are used to distinguish a material's burning characteristics after
test specimens have been exposed to a specified test flame under controlled laboratory
conditions. These classifications typically apply to materials used in manufacturing
enclosures, structural parts, and insulators found in consumer electronic products.
A material classified as 5VA or 5VB is subjected to a flame ignition source that is
approximately five times more severe than that used in the V-0, V-1, V-2 and HB tests.
Furthermore, specimens in 5VA or 5VB may not drip any flaming particles and 5VA rated
specimens may not develop any burn-through holes during the test.
Data Sheet November 2012
purposes. Un‘ess otherwise noted, a“ tests are performed at room temperature.
3M™ Flame Barrier FRB-NT Series
2 of 4
Typical Properties
Technical information provided consists of typical product data and should not be used for specification
purposes. Unless otherwise noted, all tests are performed at room temperature.
Property Units Test
Method FRB-NT076 FRB-NT102 FRB-NT127 FRB-NT178 FRB-NT254 FRB-NT381
Nominal Thickness mm
mil ASTM D-645 0.076
3.0 0.102
4.0 0.127
5.0 0.178
7.0 0.254
10.0 0.381
15.0
Color
Beige &
white,
marbled
Beige &
white,
marbled
Beige &
white,
marbled
Beige &
white,
marbled
Beige &
white,
marbled
Beige &
white,
marbled
Physical Properties
Basis Weight g/m2
lb/yd2 ASTM D-202 103
0.19 156
0.29 195
0.36 274
0.49 376
0.7 561
1.04
Density g/cc 1.4 1.5 1.5 1.5 1.5 1.5
Flame Rating
(UL File E65069) Flammabi
lity rating UL94 V-0, 5VA V-0, 5VA V-0, 5VA V-0, 5VA V-0, 5VA V-0, 5VA
Relative Thermal
Index, Component,
Electrical °C UL 746B 140 140 140 140 140 140
Relative Thermal
Index, Component,
Mechanical without
impact
°C UL 746B 130 130 130 130 130 130
Moisture Absorption % ASTM D-644 < 1 < 1 < 1 < 1 < 1 < 1
Dimensional
Shrinkage, (150 °C),
MD % ASTM D-
2305 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3
Dimensional
Shrinkage, (200 °C),
MD % ASTM D-
2305 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3
Thermal Conductivity
(180 °C) W/mK ASTM E-
1530 0.15 0.17 0.17 0.18 0.21 0.25
Electrical Properties
High-Voltage Arc
Tracking Rate (HVTR) PLC
assigned UL 746A 0 0 0 0 0 0
Comparative Tracking
Index (CTI) PLC
assigned UL 746A 0 0 0 0 0 0
Hot Wire Ignition
(HWI) PLC
assigned UL 746A 4* 4* 4* 4* 4* 4*
High Current Arc to
Ignition (HAI) PLC
assigned UL 746A 2 2 2 2 2 2
Glow wire ignition
temperature (GWIT) °C IEC 60695-
2-13 990 990 990 990 990 990
Glow wire flammability
index (GWFI) °C IEC 60695-
2-1 960 960 960 960 960 960
High Volt, Low Current
Arc Resistance PLC
assigned ASTM D-495 4 4 4 4 4 4
Dielectric
Breakdown Voltage kV ASTM D-149 1.1 2.6 3.1 3.3 5.0 8.0
Dielectric
Breakdown Strength V/mil ASTM D-149 370 650 620 470 500 530
* - Materials that do not comply with the minimum hot-wire ignition levels may be evaluated by an abnormal
overload test or the glow-wire end-product test, per UL 746C
3M™ Flame Barrier FRB-NT Series
3 of 4
Property Units Test
Method FRB-NT076 FRB-NT102 FRB-NT127 FRB-NT178 FRB-NT254 FRB-NT381
Mechanical
Properties
Nominal Thickness mm
mil ASTM D-645 0.076
3.0 0.102
4.0 0.127
5.0 0.178
7.0 0.254
10.0 0.381
15.0
Tensile
Strength, MD lb/inch
N/cm ASTM D-828 17
30 28
49 31
54 41
72 53
93 100
175
Tensile
Strength, CD lb/inch
N/cm ASTM D-828 8
14 14
25 16
28 22
39 34
60 58
102
Elongation to Break,
MD % ASTM D-828 1.5 1.5 1.5 1.5 1.5 2.0
Elongation to Break,
CD % ASTM D-828 1.1 1.1 1.1 1.1 1.1 2.0
Elmendorf
Tear, MD g
N ASTM D-689 40
0.4 88
0.9 108
1.1 172
1.7 280
2.7 534
5.2
Elmendorf
Tear, CD g
N ASTM D-689 60
0.6 132
1.3 142
1.4 302
3.0 354
3.5 734
7.2
Typical Outgassing Results for 3M™ Flame Barrier FRB-NT254 (3M Test Report ID# 158824)
Technical information provided consists of typical product data and should not be used for specification
purposes.
Gas Chromatography/Mass Spectroscopy (GC/MS) Outgassing
Dynamic headspace analysis of volatile components collected during a 3 hour at 120 °C heat cycle using a
Markes micro-CTE cell and Tenax adsorbent tubes. Analysis was by a Markes Ultra desorber coupled to an
Agilent 6890 gas chromatograph / 5975 mass spectrometer.
Total volatiles < 22 ppm by mass.
A more detailed test report may be provided on request.
3M™ Flame Barrier FRB-NT Series
4 of 4
Shelf Life & This product has a 5-year shelf life from date of manufacture when stored in a humidity
Storage controlled storage (from 10°C / 50°F to 27°C / 80°F and <75% relative humidity)
Availability For availability, please contact your local distributor. Names and addresses are
available from 3M.com/electrical [Where to Buy] or call 1-800-676-8381.
Important Notice All statements, technical information, and recommendations related to 3M’s products are based on
information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this
product, you must evaluate it and determine if it is suitable for your intended application. You assume all
risks and liability associated with such use. Any statements related to the product which are not contained
in 3M’s current publications, or any contrary statements contained on your purchase order shall have no
force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M.
Warranty; Limited This product will be free from defects in material and manufacture at the time of purchase. 3M
Remedy; Limited MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
Liability MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the
warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M
product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be
liable for any indirect, special, incidental or consequential loss or damage arising from this 3M
product, regardless of the legal theory asserted.
3M is a trademark of 3M Company.
All other trademarks are property of their respective owners.
30
Electrical Markets Division
6801 River Place Blvd.
Austin, TX 78726-9000 Please recycle.
800 676 8381 © 3M 2012 All rights reserved.
FAX 800 828 9329 78-8141-5277-9 Rev C