QUALIFICATION TABLE – CATEGORY 1
QUALIFICATION TABLE – CATEGORY 2
*Initial Limit
*Initial Limit
TEST TPC series (Temperature range -55ºC to +125ºC)
Condition Characteristics
Endurance
Apply rated voltage (Ur) at 85ºC and / or category
voltage (Uc) at 125ºC for 2000 hours through a circuit
impedance of ≤0.1Ω/V. Stabilize at room temperature
for 1-2 hours before measuring.
Visual examination no visible damage
DCL 1.25 x initial limit
ΔC/C within ±10% of initial value
DF 1.5 x initial limit
ESR 1.5 x initial limit
Humidity
Store at 40ºC and 90-95% relative humidity for 1344
hours, with no applied voltage. Stabilize at room
temperature and humidity for 1-2 hours before
measuring.
Visual examination no visible damage
DCL initial limit
ΔC/C within ±5% of initial value
DF 1.2 x initial limit
ESR 1.2 x initial limit
Temperature
Stability
Step Temperature°C Duration(min)
1+20 15
2 -55 15
3 +20 15
4+85 15
5 +125 15
6 +20 15
+20ºC -55ºC +20ºC +85ºC +125ºC +20ºC
DCL IL* n/a IL* 10 x IL* 12.5 x IL* IL*
ΔC/C n/a +0/-10% ±5% +10/-0% +15/-0% ±5%
DF IL* 1.5 x IL* IL* 1.5 x IL* 2 x IL* IL*
ESR IL* 1.25 x IL* IL* 1.25 x IL* 2 x IL* IL*
Surge
Voltage
Apply 1.3x rated voltage (Ur) at 85°C for 1000 cycles
of duration 6 min (30 sec charge, 5 min 30 sec
discharge) through a charge / discharge resistance of
1000Ω
Visual examination no visible damage
DCL initial limit
ΔC/C within ±10% of initial value
DF initial limit
ESR initial limit
TEST TPC series (Temperature range -55ºC to +125ºC)
Condition Characteristics
Endurance
Apply rated voltage (Ur) at 85ºC and / or category
voltage (Uc) at 125ºC for 2000 hours through a circuit
impedance of ≤0.1Ω/V. Stabilize at room temperature
for 1-2 hours before measuring.
Visual examination no visible damage
DCL 1.25 x initial limit
ΔC/C within ±15% of initial value
DF 1.5 x initial limit
ESR 1.5 x initial limit
Humidity
Store at 40ºC and 90-95% relative humidity for 1344
hours, with no applied voltage. Stabilize at room
temperature and humidity for 1-2 hours before
measuring.
Visual examination no visible damage
DCL initial limit
ΔC/C within ±10% of initial value
DF 1.2 x initial limit
ESR 1.2 x initial limit
Temperature
Stability
Step Temperature°C Duration(min)
1+20 15
2 -55 15
3 +20 15
4+85 15
5 +125 15
6 +20 15
+20ºC -55ºC +20ºC +85ºC +125ºC +20ºC
DCL IL* n/a IL* 10 x IL* 12.5 x IL* IL*
ΔC/C n/a +0/-15% ±5% +15/-0% +20/-0% ±5%
DF IL* 1.5 x IL* IL* 1.5 x IL* 2 x IL* IL*
ESR IL* 1.25 x IL* IL* 1.25 x IL* 2 x IL* IL*
Surge
Voltage
Apply 1.3x rated voltage (Ur) at 85°C for 1000 cycles of
duration 6 min (30 sec charge, 5 min 30 sec discharge)
through a charge / discharge resistance of 1000Ω
Visual examination no visible damage
DCL 1.5 x initial limit
ΔC/C within ±15% of initial value
DF 1.5 x initial limit
ESR 1.5 x initial limit