batgp Atop Technologies, Inc. Hardware Installation Guide Version 1.1 Tei EBB-36508137 Fax 8867375508131 www alap mm m F/N Installation Overview 2‘ Package Check List @bfi $3 T o o o in mm QM §i Qi Q} <—> <—>
EF24 Series
89900482G
Updated in July, 2015
Industrial Ethernet to Fiber Repeater
The device’s appearance is as in the figure below.
If you have purchased the wall mount kit,
proceed to place the screws on the back of
the device as show in (Fig. 1).
1.
Next we can then proceed to connect the
device to the LAN (switch or PC, depend-
ing on the case), take care on using the
RJ-45 connector; after this we can then
proceed to the device’s settings
5.
You can then choose whether to plug in the
other peripheral ports at this point or do it
later depending on the actual location of the
device or level of comfort for performing such
operation.
3.
Once the plate has been firmly put in place,
proceed to mount the whole device as
shown in (Fig. 3).Proceed to (Fig. 4) if you
want to remove the device from DIN-Rail.
The openings to the sides are for the device’s
heat dissipation, please never obstruct or
cover them with any objects or try to insert
any objects through them.
4.
2. Although internal grounding has been done
inside, in order to ensure overall maximum
performance and protect your device, it is still
strongly advised to ground the device proper-
ly; hazardous ESD can come into contact
and damage your equipment. On the power
terminal block, there is a terminal for Frame
Ground, you can choose whether to connect
it to the grounding or you may opt to connect
to the grounding screw next to the terminal
block ( the one chosen should be connected
at all times ) (Fig. 2)
(Fig. 1)
(Fig. 2)
(Fig. 3)
(Fig. 4)
1
2
Inside the package you will find the following items:
Never install or work on electrical or cabling during periods of
lightning activity. Never connect or disconnect power when
hazardous gases are present.
Caution:
CLASS 1 LASER PRODUCT. Do not stare into the laser!
Warning:
Hot Surface Do Not Touch.
RESTRICTED ACCESS AREA: The equipment should only be
installed in a Restricted Access Area.
Product Layout
Front View
EF24-1G-2SFP EF24-1G-2Fm-SC-550M
EF24-1G-2Fs-SC-10
1. CT-TML LED
2. PWR2 LED
3. PWR1 LED
4. 10/100/1000 Base-T(X)
RJ-45 Port
5. Fx1_Link LED
6. Fx1_OAM LED
7. Tx_LLCF LED
8. Fx2_Link LED
9. FP/MC LED
10. Fx_LLCF LED
11. 100 Base-FX or 1000 Base-X
SFP Slots
12. 100/1000 Base-X SC connectors
Industrial Ethernet to Fiber Repeater x 1
5-Pin 5.08mm Lockable Terminal Block
(Already mounted to the device) x 1
DIN-Rail Kit (Already mounted to the device) x 1
SFP Protective caps x 2 (For SFP model only)
Installation Guide with Warranty Card x 1
5
8
7
6
9
10
11
1 2 3
5
8
7
69
10
12
1 2 3
100 Base-FX or 1000 Base-X Fiber Optics SFP Slot
Caution
The SFP slot should be used in conjunction with a MSA compliant optical transceiver.
SFP Slot
SFP LC Connector Port Connection for Single-mode & Multi-mode modules
Tx
Rx
Rx
Tx
Cable Wiring
Top View
1
2
3
4
6
5
1. Terminal for PWR2
2. Terminal for PWR1
3. Frame Ground
4. DIP Switches
5. Grounding Screw
6. Loopback test Button
1000 Base-SX / LX Fiber Port
SC Port connection for Multi-mode or Single-mode
Tx
Rx
Rx
Tx
Cable Wiring
Rx
Tx
Rx
Tx
Cable Type
Multi-mode : 50/125μm or 62.5/125μm fiber patch cord cable
Single-mode : 9/125μm fiber patch cord cable
Unit Dimensions and Layout (unit=mm) Warranty Period Warranty Condiliuns fl RMA and Shigging Costs Reimbursement ‘LMLLILMMJ U a; flféiizéiizg i Limited Lia g
LED Indicators
CT-TML
FP/MC
Fx1_Link
Fx2_Link
Fx1_OAM
Fx_LLCF
Tx_LLCF
TX_Link/Act
TX_Speed
Green
Green
Green
Green
Green
RED
Green
Yellow
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Blinking
ON
OFF
Blinking
ON
OFF
ON
Blinking
ON
OFF
Power is being supplied through this power input
Power is not supplied through this power input
The device operates as a center media converter
The device operates as a terminal media converter
Fiber repeater mode
Media converter mode
The link is connected and no traffic is detected
The link is disconnected
Data is transmitting or receiving
The test passed (LED ON after testing for 3 seconds)
The test failed (LED OFF after testing for 3 seconds)
The loopback test is in progress
The Fiber/Copper port is forced to link down
by LLCF
The Fiber/Copper port is not forced to link down
by LLCF
The link is connected and no traffic is detected
Data is transmitting or receiving
The link is connected at 1000 Mbps.
The link is connected at 10 or 100 Mbps
if TX_Link/Act is ON or blinking
Color Status
LED Description
PWR1
PWR2
Note: The device will read the DIP switch values only at the device’s
initialization time. Please ensure to power OFF and power ON the device
to allow the new DIP switch values to take effect.
DIP Switch
Pin
1
2
3
4
5
6
7
8
Mode
Function Mode
Fiber Speed
Link Transparency
Terminal/ Center mode
Power Save Mode
Fiber Auto Negotiation
Jumbo Frame (9KB)
Cut-Through Mode
OFF
Media Converter
1000Base-X
Disable
Terminal
Disable
Enable
Disable
Disable
ON
Repeater
100Base-FX
Enable
Center
Enable
Disable
Enable
Enable
Top View
Bottom View
Side ViewRear View
Front View
EF24-1G-2SFP EF24-1G-2Fm-SC-550M
EF24-1G-2Fs-SC-10
The wall mount kit illustrated in this document is for reference only and is not
included in the package.
Warranty Policy
Warranty Conditions
Products supplied by Atop Technologies are covered in this warranty for
sub-standard performance or defective workmanship. The warranty is
not, however, extended to goods damaged in the following
circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock,earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number from Atop
before shipping the goods to be repaired to Atop. When in normal use,
a sold product shall be replaced with a new one within 3 months after
purchase. The shipping cost from the customer to Atop will be
reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop
whether to replace the unit with a new one; normally, as long as a
product is under warranty, all parts and labor are free of charge to the
customers.
After the warranty period, the customer shall cover the cost for parts
and labor.Three months after purchase, the shipping cost from the
customer to Atop will not be reimbursed, but the shipping cost from
Atop to the customer will be paid by Atop.
Limited Liability
Atop shall not be held responsible for any consequential losses from
using Atop’s product.
If the device requires servicing of any kind, you may need to disconnect
and remove it from its mounting. The initial installation should be done in a
way that makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables.
Be careful when handing the so as to not trip over
■ Do not under any circumstance insert foreign objects of any kind into the
heat dissipation holes located in the different faces of the device. This may
not only harm the internal layout but might cause harm to you as well.
Don not under any circumstance open the device for any reason. Please
contact your dealer for any repair needed or follow the instructions on
section of your User’s Manual.
Field Maintenance and Service
Any changes to this material will be announced on Atop website. ─
The warranty certification will not be effective until an authorized stamp
issued by Atop’s overseas agents.
Purchase Date: / / (yyyy/mm/dd)
Serial Number
Atop Customer Services and Supports
1. Please contact your local dealers or Atop Technical Support Center at
the following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail
account
Web Sitewww.atop.com.tw, e-mailservice@atop.com.tw
Web Sitewww.atop.com.cn, e-mailservice@atop.com.cn
Warranty
5 Years
3 Years
Product Categories
Ethernet Switches
Wireless
Serial Device Servers
Modbus Gateways
Embedded Device Servers
Media Converters
DIN-Rail Power Supplies
Power Adaptors
Antennas
Other Accessories
1 Year
Warranty Period