In an ideal converter, a change of 1 LSB of digital code corresponds to a change of exactly 1 LSB of analog signal. In real life the analog value may be larger or smaller - this deviation from the ideal is known as Differential Non-Linearity (DNL). The DNL at each code transition may be different, and the value on the data sheet is the worst case.